Products-Urit

DH-36


Features: 3-part differentiation, 21 parameters Only 9ul sampling volume Up to 60 samples per hour 50,000 sample results, including parameter, histogram, and patient information Venous whole blood, anticoagulant peripheral whole blood and pre-diluted blood Technical Specifications: Principles Electrical impedance method (WBC/RBC/PLT) and cyanide free (HGB) method Pulse baseline tracking technology, waveform discrimination technology, digital sheath flow technology and intelligent floating threshold technology Dual-channel is used for counting Parameters WBC, Lym%, Mid#, Gran#, Lym%, Mid%, Gran%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, PDW, MPV, PCT,P-LCC , P-LCR, 3 histograms, alarm for abnormal erythrocytes, leukocyte, and platelet Throughput Up to 60 samples per hour Sample Volume Minimum volume 9 ul Performance Carryover Repeatability Linearity WBC =0.5% =2.0% (7-15×109/L) 0.00-300×109/L RBC =0.5% =1.5% (3.5-6.0×1012/L) 0.00-8.5×1012/L HGB =0.5% =1.5% (110-180g/L) 0-250g/L PLT =1.0% =4.0% (150-500×109/L) 0.00-3000×109/L Data Storage Capacity Up to 50,000 results including parameter, histogram, and patient information Communication Four USB ports and Bi-directional LIS connection Operating Environment Temperature: 15oC-30oC Humidity: 30-85% Air Pressure: 70-106 kPa Power Requirement A.C. 100-240V =300VA 50/60Hz Dimension and Weight 410mm(L) × 353mm(W) × 471mm(H) Weight: 25kg


DF-50


Features: Laser scatter + Chemical dye + Flow cytometry 5-partdifferentiation, 27 parameters Up to 60 samples per hour Independent channel for Basophil measurement 10.4 inches high resolution TFT touch screen Powerfulcapability to flag abnormal cells Largestorage capacity: up to 50,000 samples Recommended or customizable decision rules for re-exam abnormal samples SupportUSB/LAN /bi-directional LIS and HL7 Support external inkjet and Laser Printer with various template&user defined template Performance: Parameter Linearity Range Precision Carryover WBC 0-300*109/L _2%(4-15*109/L)_0.5% RBC 0-8.5*1012/L _1.5%(3.5-6.0*1012/L)_0.5% HGB 0-250g/L_1.5%(110-180g/L)_0.5% PLT 0-3000*109/L_4.0%(100-500*109/L)_1.0% Sample Volume: Prediluted blood 20ul, whole blood 15ul Throughput: 60 samples per hour Operating Environment: Temperature: 10oC-30oC Humidity: 20-85% Air pressure: 70kPa~106kPa Power Requirement: 100-240V 50/60Hz Dimension and Weight: 360mm(L) × 470mm(W) × 430mm(H) Weight: 28kg


DF-56


Features: 5-part differentiation, 29 parameters, 1 3D scatter gram , 3 2D scatter grams and 3 histograms Tri- angle semi-conductor Laser scatter combined with chemical dye method, advanced flow cytometry Compact, powerful and affordable Only 20ul sampling volume Up to 60 samples per hour 3 counting modes: whole blood ,capillary blood and predilute Capability to flag abnormal samples Large storage capacity: up to 100,000 samples Technical Specifications: Principles Impedance method for WBC, RBC, PLT counting Cyanide-free reagent for Hemoglobin test Flow Cytometry (FCM), Semi-conductor Laser scatter, chemical dye method, independent Basophil channel Parameters WBC, Lym%, Lym#,Mon%, Mon#,Neu%, Neu#,Eos%, Eos#, Bas%, Bas#, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, PDW, MPV, PCT,and 4 research parameters P-LCC , P-LCR, LIC%, LIC#, ALY%, ALY# 1 3D and 3 2D 3 scatter grams and 3 histograms Throughput Up to 60 samples per hour Sample Volume Whole Blood: 20ul Prediluted: 20ul Test Mode CBC CBC+DIFF Performance Carryover Repeatability Linearity WBC =0.5% =2.0% (4-15×109/L) 0.00-300×109/L RBC =0.5% =1.5% (3.5-6.0×1012/L) 0.00-8.5×1012/L HGB =0.6% =1.5% (110-180g/L) 0-250g/L PLT =1.0% =4.0% (150-500×109/L) 0.00-3000×109/L Data Storage Capacity Up to 100,000 results including numeric and graphical information Communication LAN port supports HL7 protocol Operating Environment Temperature: 15oC-30oC Humidity: 30-85% Air Pressure: 70-106 kPa Power Requirement A.C. 100-240V =300VA 50/60Hz Dimension and Weight 380mm(L) × 450mm(W) × 535mm(H) Weight: 45kg


D5-CRP


Features: Latex-enhanced scattering immunoturbidimetry +Laser scatter + Flow cytometry 5-part differentiation + CRP, 30 parameters Up to 60 samples per hour CRP reagent cooling Independent channel for Basophil measurement Powerfulcapability to flag abnormal cells Largestorage capacity: up to 100,000 samples Recommended or customizable decision rules for re-exam abnormal samples Support bi-directional LIS Research Parameters: ALY#, ALY%, LIC#, LIC% Grams: One 3-D scattergram, three 2-D scattergrams, 3 histograms Sample Volume: 20ul Sample Mode: open mode CRP linearity range: 0.2~320mg/L Reagent: DIL-A, LYA-1, LYA-2, LYA-3, CRP-R1, CRP-R2 Dimension and Weight: 380mm(L) × 450mm(W) × 535mm(H) Weight: 45kg Working Environment: Voltage :100 ~ 240 V;50/60Hz Rated Power :=250VA Envioronment Temprature:15?~ 30? Relative Humidity :30% ~ 85% Atmospheric Pressure:70kPa ~ 106kPa


DH-76


Features: 5-part differentiation, 29 parameters, 1 3D scatter gram , 3 2D scatter grams and 3 histograms Tri- angle semi-conductor Laser scatter combined with chemical dye method, advanced flow cytometry Compact, powerful and affordable Only 20ul sampling volume Up to 80 samples per hour 3 counting modes: whole blood ,capillary blood and prediluted Capability to flag abnormal samples Large storage capacity: up to 100,000 samples Technical Specifications: Principles Impedance method for WBC, RBC, PLT counting Cyanide-free reagent for Hemoglobin test Flow Cytometry (FCM), Semi-conductor Laser scatter, chemical dye method, independent Basophil channel Parameters WBC, Lym%, Lym#,Mon%, Mon#,Neu%, Neu#,Eos%, Eos#, Bas%, Bas#, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, PDW, MPV, PCT,and 4 research parameters P-LCC , P-LCR, LIC%, LIC#, ALY%, ALY# 1 3D and 3 2D 3 scatter grams and 3 histograms Throughput Up to 80 samples per hour Sample Volume Whole Blood: 20ul Prediluted: 20ul Test Mode CBC CBC+DIFF Performance Carryover Repeatability Linearity WBC =0.5% =2.0% (4-15×109/L) 0.00-300×109/L RBC =0.5% =1.5% (3.5-6.0×1012/L) 0.00-8.5×1012/L HGB =0.6% =1.5% (110-180g/L) 0-250g/L PLT =1.0% =4.0% (150-500×109/L) 0.00-3000×109/L Data Storage Capacity Up to 100,000 results including numeric and graphical information Communication LAN port supports HL7 protocol Operating Environment Temperature: 15oC-30oC Humidity: 30-85% Air Pressure: 70-106 kPa Power Requirement A.C. 100-240V =300VA 50/60Hz Dimension and Weight 620mm(L) × 620mm(W) × 535mm(H) Weight: 56kg


adad


awdadw